Posters

Presenting Author

Rachael A. Turner

Presentation Type

Poster

Discipline Track

Clinical Science

Abstract Type

Research/Clinical

Abstract

Background: Hip precautions are traditionally employed after posterior total hip arthroplasty (THA). The primary purpose was to investigate the necessity of hip precautions after posterior approach THA. We hypothesized that eliminating precautions in patients that achieved appropriate intraoperative stability would not increase the dislocation rate.

Methods: Randomized controlled trial of 346 consecutive eligible patients undergoing primary THA with a mean follow-up of 2.3 years (range 11 months to 3.7 years). Exclusion criteria: lumbar fusion, scoliosis, abductor insufficiency, inability to achieve intraoperative stability with combined 90° flexion and 45° internal rotation in 0° adduction. Fisher's exact test was used to compare dislocation rates between the hip precaution (HP) control group and no hip precaution (NP) study group. In addition, Mann–Whitney U test was used to compare differences in HOOS JR scores at 2, 6, 12 weeks between groups.

Results: The dislocation rate was not increased in the NP (0/172: 0%) group compared to the HP group 4/174 (2.29%) (P = .418). All dislocations occurred in the precautions group, two of which required revision. There were no differences in mean HOOS Jr. scores at any 2, 6, or 12 weeks (P > .05 at all timepoints) (secondary outcome).

Conclusion: Eliminating hip precautions in patients undergoing posterior approach THA that achieve 90°/45°/0° intraoperative stability does not increase the rate of dislocation. In fact, every dislocation occurred in patients receiving hip precautions. Short-term patient-reported outcome measures were not affected by hip precautions. Surgeons may discontinue the use of hip precautions as the standard of care in patients achieving 90°/45°/0° stability.

Academic/Professional Position

Medical Student

Included in

Orthopedics Commons

Share

COinS
 

Patients Achieving 90°/45°/0° Intraoperative Stability Do Not Require Hip Precautions Following Posterior Approach Total Hip Arthroplasty: A Prospective Randomized Study

Background: Hip precautions are traditionally employed after posterior total hip arthroplasty (THA). The primary purpose was to investigate the necessity of hip precautions after posterior approach THA. We hypothesized that eliminating precautions in patients that achieved appropriate intraoperative stability would not increase the dislocation rate.

Methods: Randomized controlled trial of 346 consecutive eligible patients undergoing primary THA with a mean follow-up of 2.3 years (range 11 months to 3.7 years). Exclusion criteria: lumbar fusion, scoliosis, abductor insufficiency, inability to achieve intraoperative stability with combined 90° flexion and 45° internal rotation in 0° adduction. Fisher's exact test was used to compare dislocation rates between the hip precaution (HP) control group and no hip precaution (NP) study group. In addition, Mann–Whitney U test was used to compare differences in HOOS JR scores at 2, 6, 12 weeks between groups.

Results: The dislocation rate was not increased in the NP (0/172: 0%) group compared to the HP group 4/174 (2.29%) (P = .418). All dislocations occurred in the precautions group, two of which required revision. There were no differences in mean HOOS Jr. scores at any 2, 6, or 12 weeks (P > .05 at all timepoints) (secondary outcome).

Conclusion: Eliminating hip precautions in patients undergoing posterior approach THA that achieve 90°/45°/0° intraoperative stability does not increase the rate of dislocation. In fact, every dislocation occurred in patients receiving hip precautions. Short-term patient-reported outcome measures were not affected by hip precautions. Surgeons may discontinue the use of hip precautions as the standard of care in patients achieving 90°/45°/0° stability.

blog comments powered by Disqus
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.